Multistage Pressure Booster Pump 1 Kw

Automatic Multi-Stage Water Pressure Booster Pump 1 Kw                            Model EEZI 5-5

Experience the silent operation of our horizontal multi-stage centrifugal pump—compact design, 100% anticorrosive wet end ensuring zero water contamination. Equipped with a multifunction digital pressure switch for optimal performance.

Quiet Running Water Pressure Booster Pump 1 Kw

Applications:

To work with clean water in domestic applications, irrigation, commercial and light Industrial.

Materials:
  • Pump body, diffusers and impellers in stainless steel 304.
  • Motor shaft in stainless steel 304.
  • Suction and discharge in stainless steel 304.
  • Mechanical seal in graphite and steatite.
  • Motor housing in aluminum L-2521.

Motor:

  • Asynchronous, two poles.
  • IP 55 protection.

Electronic Digital Pressure Switch:

  • Digital display for setting and actual run pressure value.
  • Automatic start and stop function.
  • Run dry safety function.
  • Anti-rotor lock function. If pump not used in a 48 hr period it will run for 10 seconds.
  • Starting pressure can be selected from 0.5~4.6 bar

MODEL : EEZI-5-5

  • POWER: 1.KW , 220~240 Volt
  • Max Flow: 108 l/m
  • Max Head: 48 m
  • Max Pressure: 4.8 Bar
  • Max Amps: 6.2 amps
  • Inlet Size 32mm ( 1 1/4″ )
  • Outlet Size 25mm ( 1″ )

Complete unit with Electronic Digital Pressure Controller

PRICE : R5405.00 VAT INCL

 

CLICK ON BELOW TAB TO DOWNLOAD PUMP DATA CURVE SHEET

EEZI5-5 DATA CURVE SHEET

INSTALLATION Model : EEZI-5-5

Pump & Supply Tank

All Booster Pumps must get there supply from water from a Storage Tank. Booster Pumps cannot simply be put in line with the municipal feed. Please refer to Schematic Drawing of Pump and Tank.

Piping design

Poor piping design and installation is a common cause of poor centrifugal-pump performance or failure. Poor piping can result in:

  • Cavitation
  • Performance dropout
  • Impeller failure
  • Bearing and mechanical seal failures
  • Cracked casings
  • Leaks
  • Spills
  • Fires
Suction piping

Suction piping is more important than discharge piping.

Suction Pipe size and elimination of air pockets

The EEZI-5-5 has a 1 1/4 inch Inlet. Piping should be at least one nominal pipe size larger than the pump suction Inlet. Velocities should be less than 2 to 3 ft/sec, and the head loss as a result of friction should be less than 1 ft per 100 ft of equivalent piping length.

Suction lines should be short and free of all unnecessary turns. For flooded suctions, piping should be continuously sloping downward to the pump suction so that any vapour pockets can migrate back to the source vessel. For static lifts, the piping should be continuously sloping upward with no air pockets (install gate valves in horizontal position).

If a gate valve is to be install between Pump and Tank it is recommended the pipe size and gate valve be increased to 1½ inch and reduced going into the pump back to 1 inch. No non-return valves, strainers or filters are to be fitted between Pump and Tank.

The pump already has a non-return valve fitted to it and cannot push back on the Tank. Strainers must be fitted on the pipe work that enters the Tank. Filters can be fitted before entering Tank or on the outlet side of the pump. Make sure that filters can handle the pressure of the pump.

Upstream elbow considerations

When making upstream orientation changes, only long-radius elbows should be used. They should not be connected directly to the pump suction flange, and a minimum of at least two to five pipe diameters of straight pipe should be between the suction flange and the elbow and between successive elbows.

This reduces swirl and turbulence before the fluid reaches the pump. Otherwise, separation of the leading edges may occur, with consequent noisy operation and cavitation damage. The outlet pipe may be reduced to suit the application. Important to remember the smaller the outlet pipe the less volume of water can be pushed.

Cover the Pump

The Pump must be covered and protected from the elements. Pumps incorrectly installed are not covered under the Manufactures Warranty.

Electrical Connection

Electrical Connections to the Pump are to be done by a qualified person.

 

Our expert installation team will install your pump quickly and professionally.

We can courier your pump to all major towns and cities in South Africa within two to four working days. Email us with your delivery address details, model of pump and we will quote you for pump and delivery accordingly.